2019C Cat Caterpillar ET Cat ET 3 Software Caterpillar Electronic Technician With KeyGen Activation and Installation Video
Note: After receiving the payment, we will send you the software,keygen and installation video by email.
Top 3 reasons to get Caterpillar ET 2019C Software:
- Latest Caterpillar ET Software to work with CAT/CAT3 Truck Scanner
- With KeyGen Active and Install Video
- Support Multi-languages:English, Chinese, Danish, French, German, Italian, Japanese, Portuguese, Russian, Spanish
Cat et Caterpillar Electronic Technician Software 2019C V1.0:
Type of catalogue: Caterpillar Electronic Technician Diagnostic
Software Make: Caterpillar
Region: WorldWide all region
Operating System: Windows 7 32 bit, Wnidows 7 64 bit, Windows 8/8.1 32 bit, Windows 8/8.1 64 bit, Windows 10 32 bit, Windows 10 64 bit
Publication date: 10.2019 year
2019C Cat et Diagnostic Software PC Requirements:
Recommended Configurations:PC containing a 2.0GHz dual-core processor3GB RAM3GB of available hard disk drive DVD-ROM driver15.4 inch XGA Screen (1280x1024 compatible)Microsoft Windows™ 7 Professional or Windows 8 Professional, Windows 10 Professional (Not tested with Home Edition) (Note: Windows 8 RT is not supported) RS232 port with 16550AF UART or compatible (for use with Comm Adapter II)USB 1.1 or 2.0 port (for use with Comm Adapter 3)Ethernet RJ45 connectorBuilt in pointing device or mouseFor security purposes, Microsoft Internet Explorer version 9 or newer is recommended.
Caterpillar ET Software 2019 Function:This diagnostic app allows you to:View active and logged diagnostics.View events where irregularities occurred and were logged by the ECM.View the status of a group of parameters (temperatures, pressures, etc.) simultaneously.Record and log performance data.Graph a group of status parameters.View the current configuration of an ECM.Change ECM configurations.Perform diagnostic tests.Perform calibrations.Print reports and diagnostic results.Please keep in mind that some ecm settings for example, speed limit requires factory password. The factory password generator is not included in this application
What's NewWhat's New - 2019CIndication of Selected Communications Adapter
The service tool now displays the selected communications adapter when the service tool is disconnected. The adapter name is displayed in the status area at the bottom right of the service tool window.
End of Support for Windows 7
Microsoft is ending extended support for Windows 7 as of January 2020. The service tool will be ending support for Windows 7 as of the 2020A release.
What's New - 2019BAutomatic Product Status Report (PSR) UploadThe service tool includes a new tool that automatically uploads Product Status Reports. The tool scans for newly generated Product Status Reports and uploads them when an internet connection is available. The default is that automatic report uploading is enabled. The Preferences dialog has an option to disable the tool.
What's New - 2019AECM Naming ChangesCertain ECMs connect to the service tool over two data links at the same time. The service tool shows a message popup when the ECM is only detected on one link. The service tool has been changed to add the text **INCOMPLETE** in the ECM name when the connection is incomplete. Service tool features that display a connection icon also use a new icon for an incomplete connection.
What's New - 2018CNo significant new features or feature enhancements
What's New - 2018BCEOS Fleet Configuration File TOPA CEOS (Customer Electronic Option Selection) Fleet Configuration File can be created/modified for an engine using the Service Tool. This is available in connected and disconnected mode.Error When Launching Service ToolThere is a Microsoft issue with upgrading libraries during an installation involving certain versions of the C++ redistributable. After a successful service tool installation, when trying to run the service tool for the first time, one of the following errors may occasionally appear: “The entry point could not be located in api-ms-win-crt-runtime” or “The program can't start because mfc140u.dll is missing from your computer.” If either of these messages is displayed, please let us know and we will send you to step by step troubleshooting guide. This procedure requires administrator rights.Service Tool License Corruption Issues with Windows 10 UpdatesWindows 10 updates 1709 and 1803 will corrupt service tool licenses. Future Window 10 updates may do the sameIf either of license error messages is displayed, please let us know and we will send you to step by step troubleshooting guide.
What's New - 2018ATrainer Update - 988K XE Wheel LoaderThe 988K XE Wheel Loader has been added to the Trainer application.
What's New - 2017CPreferences Option to Save a Product Status Report to PDFThe Preferences dialog for the Product Status Report has changed. The dialog contains a new checkbox to automatically save a Product Status Report as a PDF file when the report is created. The service tool will continue to automatically save Product Status Reports as an XML file.
What's New - 2017BProduct Status Report UpdatesThe Product Status Report has been updated to include certain history features supported by the ECM, such as the after-treatment Regeneration History and the Service Test History.Winflash Screen UpdateThe screen for the Winflash feature has been updated. A new Expand All button opens all sections of the screen to show all details for ECMs detected by WinFlash. A new Collapse All button hides all sections of the screen, except for header rows showing detected ECM names.
PC, Communication Hardware, and Cable RequirementsTo run the service tool, the next PC, communication hardware, and cable requirements must be met. NOTE: The minimum PC Configurations should not be used as a standard when buying new personal computers for service tool purposes. If the existing equipment meets these minimum requirements, it will run the service tool.
PC RequirementsRecommended ConfigurationsPC containing a 2.0 GHz dual-core processor3GB RAM3GB of the available hard disk driveDVD-ROM drive (optionally)15.4-inch XGA Screen (1280x1024 compatible)Microsoft Windows™ 7 Professional or Windows 8 Professional, Windows 10 Professional (Not tested with Home Edition) (Note: Windows 8 RT is not supported)RS232 port with 16550AF UART or compatible (for use with Comm Adapter II)USB 1.1 or 2.0 port (for use with Comm Adapter 3)Ethernet RJ45 connectorBuilt-in pointing device or mouseFor security purposes, Microsoft Internet Explorer version 11 or newer or Microsoft Edge is recommended.Note: The most recent version of Microsoft Internet Explorer may not be validated to work with the service tool.Wi-Fi (for the Wireless Comm Adapter 3)
Minimum ConfigurationsPC containing a Pentium 2 GHz processor or greater1GB RAM500MB of an available hard disk driveCD-ROM driveSuper VGA monitor or display (1024x768)Microsoft Windows™ 7 Professional or Windows 8 Professional, Windows 10 Professional (Not tested with Home Edition) (Note: Windows 8 RT is not supported)RS232 port with 16550AF UART or compatible (for use with Comm Adapter II)USB 1.1 or 2.0 port (for use with Comm Adapter 3)Ethernet RJ45 connectorBuilt-in pointing device or mouseFor security purposes, Microsoft Internet Explorer version 9 or newer is recommended. Note: The most recent version of Microsoft Internet Explorer may not be validated to work with the service tool.
Communication HardwareCaterpillar Communication Adapter III Configuring Cat Electronic Technician to use the Communication Adapter 3For Cat Electronic Technician to work with the Communication Adapter 3, the settings must be changed to select the Communication Adapter 3 as the Communication Interface Device:Step 1 Start Cat Electronic Technician.Step 2 Click the Stop Connect button when it appears.Step 3 Select the Utilities menu.Step 4 Choose “Preferences > Modify...”.Step 5 Select the Communications tab.Step 6 Select Cat Comm Adapter 3 (RP1210) and click OK.NOTE: Because a growing number of products require multiple data link service, the “Enable Dual Datalink Service” checkbox has been pre-selected.Servicing ECMs on more than one data link requires this check box to be enabled.Failure to do this will result in undetected ECMs and reduced functionality.User Comment First Prev Next Last